Electricity Units Calculator per Appliance
Quick answer: Units (kWh) = watts × hours ÷ 1,000. A 75 W fan for 12 hours uses 0.9 units a day (27 a month). A 1.5 ton inverter AC (up to 1200 W) for 8 hours uses up to 9.6 units a day. Pick your appliances above, set how many and hours a day, and see monthly units with an estimated bill.
Formula and examples
- Units per day = watts × quantity × hours ÷ 1,000.
- Units per month = units per day × 30.
- Charger: a 5 W mobile charger for 3 hours = 0.015 units – tiny.
- Geyser: 2,000 W for 2 hours = 4 units a day, 120 a month.
Lahore region customers can view and print the LESCO duplicate bill with the 14-digit reference number.
A typical home in summer
| Appliance | Qty | Hours/day | Units/day | Units/month |
|---|---|---|---|---|
| Ceiling fan | 4 | 12 | 3.60 | 108 |
| LED bulb 12 W | 6 | 6 | 0.43 | 13 |
| Refrigerator (medium, double door) | 1 | 12 | 1.92 | 58 |
| LED TV 43 inch | 1 | 5 | 0.50 | 15 |
| Inverter AC 1.5 ton | 1 | 8 | 9.60 | 288 |
| Electric iron | 1 | 0.5 | 0.60 | 18 |
| Water motor 1 hp | 1 | 0.5 | 0.37 | 11 |
| Total | 17.0 | 511 |
Fridge hours are set to 12 because the compressor switches on and off. The AC uses less than its maximum after the room cools.
Appliance watts
| Appliance | Watts | Units per hour |
|---|---|---|
| Ceiling fan | 75 W | 0.075 |
| Inverter / BLDC ceiling fan | 30 W | 0.03 |
| Pedestal fan | 90 W | 0.09 |
| Air cooler | 185 W | 0.185 |
| Refrigerator (medium, double door) | 160 W | 0.16 |
| Deep freezer | 250 W | 0.25 |
| LED bulb 12 W | 12 W | 0.012 |
| LED tube light 18 W | 18 W | 0.018 |
| LED TV 43 inch | 100 W | 0.1 |
| Laptop | 65 W | 0.065 |
| Desktop computer | 300 W | 0.3 |
| Wi-Fi router | 10 W | 0.01 |
| Electric iron | 1200 W | 1.2 |
| Washing machine (top load / semi-auto) | 500 W | 0.5 |
| Water motor 1 hp | 746 W | 0.746 |
| Microwave oven | 1200 W | 1.2 |
| Electric kettle | 1500 W | 1.5 |
| Electric geyser (storage) | 2000 W | 2 |
| Room heater (electric) | 2000 W | 2 |
Typical running ratings; check the rating plate of your own appliance. 1 unit = 1 kWh = 1,000 watts for 1 hour.
From units to your bill
For non-protected users the whole bill is charged at the rate of the slab your total falls in, so crossing 200, 300 or 400 units can raise every unit's price. Estimate your bill with the electricity bill calculator, see per unit rates and find heavy use in peak hours. Check your meter reading against the bill: the difference between current and previous reading is your units.
Biggest savings
- AC: set 26°C, clean filters, use an inverter model. For sunny homes, solar and inverter ACs can shift daytime cooling to solar.
- Replace old fans with BLDC (30 W vs 75 W).
- Use the geyser on a timer.
- Unplug old fridges and freezers you do not need.