Quick answer: Backup hours = battery volts × Ah × usable share × inverter efficiency ÷ load watts. Lead-acid / tubular: use 50%; lithium: 90%; inverter efficiency about 85%. A 12 V 200 Ah lithium battery on 500 W lasts about 3 h 40 min; the same size lead-acid lasts about 2 h 2 min.

Advertisement

The formula with an example

Backup (hours) = V × Ah × N × DoD × 0.85 ÷ load W

  • V = battery voltage, Ah = capacity, N = number of batteries in the bank (for the same voltage, add Ah; for series, add volts).
  • DoD = how much you can safely use: 0.5 for lead-acid, 0.9 for lithium.
  • 0.85 = inverter efficiency.

Example: 12 V × 200 Ah × 0.5 × 0.85 = 1,020 Wh. With 3 fans (225 W), 4 LED bulbs (48 W) and a router (10 W) ≈ 283 W → 1,020 ÷ 283 ≈ 3.6 hours.

Backup time for common setups

Backup time examples
Battery bankLoadUsable energyBackup
1× 12 V 150 Ah lead-acid300 W765 Wh2 h 33 min
1× 12 V 200 Ah lead-acid500 W1,020 Wh2 h 2 min
2× 12 V 200 Ah lead-acid500 W2,040 Wh4 h 5 min
1× 12 V 200 Ah lithium500 W1,836 Wh3 h 40 min
1× 24 V 100 Ah lithium500 W1,836 Wh3 h 40 min
1× 51.2 V 100 Ah lithium1000 W3,917 Wh3 h 55 min
2× 51.2 V 100 Ah lithium1500 W7,834 Wh5 h 13 min

Same maths as the calculator. Old batteries, heat and high loads reduce real backup.

Advertisement

How to size a battery for your load

  1. Add watts of what you want to run in load shedding: load calculator.
  2. Multiply by hours you need: 400 W × 4 h = 1,600 Wh.
  3. Divide by DoD and efficiency: 1,600 ÷ (0.9 × 0.85) ≈ 2,090 Wh for lithium; 1,600 ÷ (0.5 × 0.85) ≈ 3,760 Wh for lead-acid.
  4. Divide by voltage for Ah: at 24 V, about 87 Ah lithium or 157 Ah lead-acid.

Lead-acid vs lithium for UPS and solar

Battery types
PointLead-acid / tubularLithium (LiFePO4)
Usable capacityAbout 50%About 90%
Typical cycle lifeHundreds of cyclesThousands of cycles
MaintenanceWater top-up (tubular)None
WeightHeavyMuch lighter
ChargingSlowerFaster, needs compatible charger / BMS

Check the warranty and cycle rating in the datasheet of the exact model.

Advertisement

Charging time from solar

Charging hours ≈ battery Wh to refill ÷ (charging panel watts × 0.8). A 2.4 kWh lithium bank from 1 kW of panels takes about 3 hours of good sun if loads are off. Hybrid systems with lithium battery solar systems handle this automatically. Size panels with the solar system calculator.

Tips

  • Do not run lead-acid flat every day – life drops fast.
  • Keep batteries in a ventilated, shaded place.
  • Match battery voltage with your inverter (12 / 24 / 48 V).
  • A battery is not strictly needed for on-grid solar; it is needed for backup.

Official sources

Questions people ask

How to calculate battery backup time?
Multiply volts by Ah, by usable share (0.5 lead-acid, 0.9 lithium) and by 0.85 inverter efficiency, then divide by load watts. The answer is hours.
How long will a 12 V 200 Ah battery last on 500 W?
Lead-acid about 2 h 2 min, lithium about 3 h 40 min, using the formula above.
How to calculate UPS load?
Add the watts of everything connected to the UPS. A UPS rated in VA gives about 0.8 × VA in watts, so keep the load below that.
How to calculate battery size for a UPS?
Wh needed = load W × hours; divide by DoD and 0.85, then by battery voltage to get Ah.
How to calculate battery backup for a solar system?
Use your night load in watts times the hours of backup you need, then apply the same formula. Solar panels then recharge the batteries in the day.
Is a battery necessary for a solar system?
Not for on-grid systems, which use the grid as storage. Batteries are needed for backup during load shedding (hybrid) or for off-grid homes.
How to calculate battery charging time by solar panel?
Divide the Wh you need to refill by the panel watts × 0.8. Example: 2,400 Wh ÷ (1,000 × 0.8) = 3 hours of strong sun.
How long will a UPS last?
Backup depends on battery size and load, not the UPS. Use the calculator above with your battery and load.
Why do lithium batteries give more backup?
They can safely use about 90% of their capacity versus about 50% for lead-acid, and keep voltage steadier under load.
Advertisement